Copper Earthing Pipe Manufacturer in India As Per BS 2871/EN 1057

Suppliers of ASME SB280 Pure Copper Earthing Electrode in Mumbai, Refer Specification
Copper Tubes for Earthing System Manufacturer in India in Various Types
Outside Diameter
17.2mm, 14.2mm , 50mm, 40mm,65mm
Copper Earthing Pipe Terminal Dimensions
40×6 , 35×6 50×6
Copper Tubes for Earthing System Length
1 to 3m or custom
Material
99.9% Pure Copper
Copper Pipe Earthing Type
GI Earthing, Copper Bonded Electrode, Copper Strip etc
Copper Bonded Earthing Electrode Standards
ASTM B75 / ASTM B68 ASTM B88 / /ASTM B280 / EN1057 or BS2871: PART 2:1972 / JIS H 3300 / DIN 8905/ 1754/IS2501
Inner Strip Dia
25×3
Pure Copper Earthing Electrode Uses
Telecom sector, Railways, Airports, Petroleum Industry
Copper Grounding Pipe Grades
C12200, TP1, T2, C1220T, C1200, TP2, C1100, C19400, C1201T, C10200, C14200, TU2, C1020T etc
Get ASTM B819 Copper Grounding Pipe stock in Seamless Form With various grades like T2, C1020T, TU2, C10200, C1100 etc. for Electric Safety at the Best Price.
| Size (mm) | Weight (kg) | Length (ft) | Total Price (INR) | Price per kg (INR) |
|---|---|---|---|---|
| 28 | 1.9 | 6 | 1045 | 550 |
| 25 | 1.7 | 6 | 935 | 550 |
| 32 | 2.2 | 6 | 1210 | 550 |
| 65 | 4.7 | 6 | 2575 | 550 |
| 40 | 2.8 | 6 | 1540 | 550 |
| 36 | 2.5 | 6 | 1375 | 550 |
| 50 | 3.6 | 6 | 1980 | 550 |
Specialises in Earth Pipe With Copper Plate in Square and Rectangular Shape With Wall thickness 0.2mm~5mm or Custom, Check HSN Code
Copper Strip in Pipe
GI Earthing Electrode
Copper Pipe with Chemical
Copper Bonded Electrode
Pure Copper Electrode
Earth Pipe With Copper Plate
Copper Earthing Electrode
Copper Grounding Pipe
60mm 3 Meter Copper Earthing Electrode
40mm 3 Meter Pure Copper Earthing Electrode
50mm 3 Meter Cu Earthing Electrode
3 Meter 80mm Copper Alloy Earthing Electrode
Copper Pipe in Pipe Technology
Copper Plate Earthing
Copper Earthing Pipe
| Length Mtr | Cu Model | Diameter ( Available ) | |
|---|---|---|---|
| MM | MM | ||
| 1 | 1000 MM | 50 | 40 |
| 2 | 2000 MM | 50 | 40 |
| 3 | 3000 MM | 50 | 40 |
| 1.5 | 1500 MM | 50 | 40 |
| Modal | Outer pipe Diameter (MM) | Terminal size | Length (Mtr.) | Inner strip |
|---|---|---|---|---|
| 50 FEPC | 50 | 40×6 | 1,2 & 3 | 25×3 |
| 40 FEPC | 40 | 40×6 | 1,2 & 3 | 25×3 |
| 80 FEPC | 80 | 540×6 | 1,2 & 3 | 25×3 |
| Length | ISI GI Pipe | OD ISI GI | Outer Pipe Thickness | Copper Terminal | Inner Pipe Thickness |
|---|---|---|---|---|---|
| Inner | Outer | ||||
| 1.0 meter | 40 mm | 100 cm x 50 mm | 14 gauge | 25 cm x 3 mm | 12 gauge |
| 2.0 meter | 40 mm | 200 cm x 90 mm | 14 gauge | 50 cm x 6 mm | 12 gauge |
| 3.0 meter | 40 mm | 300 x 90 mm | 14 gauge | 50 cm x 6 mm | 12 gauge |
| 1.5 meter | 40 mm | 150 cm x 90 mm | 14 gauge | 50 cm x 6 mm | 12 gauge |
| Product | HSN Code |
|---|---|
| Copper Earthing Pipe | 74091900 |
Find the Complete Source of Copper Bonded Earthing Electrode As Per International Standards, See Composition and Equivalent

| Alloy Name | Others | UNS | BS | BS EN |
|---|---|---|---|---|
| North America | United Kingdom | United Kingdom/Europe | ||
| C1-01 | NF A5-1-11-8-1 | C1-10-00 | C1-01 | CW-00-4A |
| C1-03 | NF A5-1-11-8-1 | C1-02-00 | C1-03 | CW-00-8A |
| C1-06 | BS-28-70-; BS-28-71-; BS-28-74 | C1-22-00-; C1-22-10-; C1-23-00 | C1-06 | CW-02-4A |
| C1-07 | C1-42-00 | C1-07 | BS-28-71-; BS-28-75 | |
| C1-09 | 2.-15-45 | C1-45-00 | C1-09 | CW-11-8C |
| C1-10 | BS-14-33-, BS-38-39 | C1-01-00 | C1-10 | CW-00-9A |
| BS | EN | ISO | DESCRIPTION |
|---|---|---|---|
| United Kingdom | Europe | ||
| C111 | CW114C | Cu-S | Sulphur copper (free machining) |
| C103 | CW008A | Cu-OF | Oxygen free high conductivity copper |
| C101 | CW004A | Cu-ETP | Electrolytic, tough pitch, high conductive copper |
| CC102 | CW106C | CuCr1Zr | Copper Chrome Zirconium |
| C101 | CW011A | Cu-Ag-2 | Silver-bearing Copper |
| C101 | CW013A | Cu-Ag-4 | Silver-bearing Copper |
| C109 | CW118C | Cu-TEP | Tellurium copper (free cutting) |
| C101 | CW012A | Cu-Ag-3 | Silver-bearing Copper |
| Standard | Copper Alloy No. | Mechanical Properties | |||
|---|---|---|---|---|---|
| Tensile strength (Mpa) | Grain Size (mm) | Elongation(%) | Temper | ||
| EN 1057 | – | O250 | – | O30 or 20 | R250 |
| O220 | – | O40 | R220 | ||
| O290 | – | O3 | R290 | ||
| JIS H3300 | C1100 | 245 ~ 325 | – | – | OL |
| O205 | – | O40 | |||
| O265 | – | – | H | ||
| C1220 | O255 | – | – | H | |
| O205 | O0.040 | O40 | OL | ||
| O205 | 0.025 ~ 0.060 | O40 | O | ||
| 245 ~ 325 | – | – | 1/2H | ||
| ASTM B88 | C11000 | O200 | O0.025 | – | O50 |
| O200 | O0.040 | – | O60 | ||
| C12200 | O250 | – | – | H58 | |
| ASTM B75 | C11000 | O205 | O0.040 | – | O50 |
| O205 | O0.040 | – | O60 | ||
| C12200 | O310 | – | – | H80 | |
| O250 | – | – | H58 | ||

There Are Numerous Crucial Steps in the Pipe Earthing Installation Process:
- Select a Well-suited Area With High Conductivity.
- Make a Hole That is About 2.5 Metres Deep.
- Put in a Galvanised Iron (Gi) Pipe Vertically.
- Use a Charcoal and Salt Mixture as a Backfill to Improve Conductivity.
- Using an Appropriate Conductor, Attach the Device to the Top End of the Gi Pipe.
- Check for Resistance Compliance in the System.
- Install Safety Precautions for the Gi Pipe’s Exposed Section.
- Keep a Record of the Installation Information for Compliance and Future Use.
- Airports, Buildings, Hotels
- Transmission and distribution systems
- Railways
- Telecom sector
- Banking Sector
- Petroleum Industry and Fuel Depot
- Substation and Power Generators
- Commercial Sector
- Equipment Body Earthing
- Manufacturing Units and Refineries
| Width and Thickness in mm |
Weight in kg.Gms | Weight in kg.Gms | Width and Thickness in mm |
Weight in kg.Gms | Width and Thickness in mm |
|---|---|---|---|---|---|
| 12 * 5 | 1.712 | 0.57 | 38 * 5 | 9.055 | 100 * 10 |
| 12 * 3 | 1.141 | 0.38 | 38 * 3 | 6.089 | 100 * 6 |
| 19 * 3 | 3.425 | 0.57 | 38 * 10 | 7.609 | 125 * 6 |
| 25 * 6 | 4.527 | 1.522 | 50 * 10 | 17.2 | 150 * 12 |
| 12 * 6 | 2.283 | 0.761 | 38 * 6 | 12.179 | 100 * 12 |
| 19 * 5 | 4.567 | 0.856 | 38 * 12 | 11.1 | 125 * 10 |
| 25 * 3 | 2.263 | 0.761 | 50 * 5 | 9.131 | 150 * 6 |
| 19 * 6 | 1.522 | 1.141 | 50 * 3 | 14.35 | 125 * 12 |
| 25 * 5 | 3.044 | 1.141 | 50 * 6 | 13.3 | 150 * 10 |
| 25 * 12 | 3.805 | 3.044 | 63 * 6 | ||
| 32 * 10 | 6.85 | 2.854 | 75 * 10 | ||
| 25 * 10 | 6.089 | 2.263 | 50 * 12 | ||
| 32 * 5 | 7.611 | 1.427 | 63 * 12 | ||
| 32 * 3 | 5.708 | 0.952 | 63 * 10 | ||
| 32 * 6 | 4.567 | 1.903 | 75 * 6 | ||
| 32 * 12 | 9.134 | 3.6 | 75 * 12 |
- Easy and Fast installation
- Designed for fast fault current dissipation
- 100% copper used for long life
- Longlife
- Low maintenance on site
- Cost Effective
- Extendable
- Less Area Consumption
- Assured Result
- Protection for Early Corrosion
- Very High Tensile Strength
Table of Content